Bowman Heat Exchanger FG100 - 5115-2C - Cupro Nickel
The Bowman Heat Exchanger FG100 - 5115-2C is an efficient shell and tube heat exchanger which is suitable for swimming pools up to 250 m³, via a boiler heat source. The cast end covers are finished in ‘C’ coat, an advanced technology coating, which is highly corrosion resistant and the unit is available with either a titanium, cupro-nickel, or stainless steel tube core.
The Bowman Heat Exchanger FG100 - 5115-2C is an efficient shell and tube heat exchanger which is suitable for swimming pools up to 250 m³, via a boiler heat source. The cast end covers are finished in ‘C’ coat, an advanced technology coating, which is highly corrosion resistant and the unit is available with either a titanium, cupro-nickel, or stainless steel tube core.
Bowman Heat Exchanger FG100 - 5115-2C - Cupro Nickel
When it comes to efficient, high-performance heat transfer for pools and spas, Bowman Heat Exchanger FG100 - 5115-2C stands out as a top choice. With thousands of units in operation worldwide—from private hot tubs to Olympic-sized pools—Bowman offers reliable and energy-efficient heat transfer solutions for both commercial and residential applications.
Product Benefits:
- Proven: heats spas and hot tubs extremely fast, reducing energy costs
- Easy to install: solvent weld end covers with thermostat pocket
- Durability: salt water and mineral rich fresh water compatible
- Simple to maintain: easy disassembly for routine maintenance
- Titanium models: full 10 year warranty on titanium materials
Specification:

| Type | Tube Material | Typical Pool Capacity | Maximum Pool Water Flow | Maximum Hot Water Temp | Max. Operating Pressure Pool Water | Max. Operating Pressure Hot Water | Weight | |||||
| m3 | gal | m3/ h | l/min | ºC | ºF | bar | psi | bar | psi | kg | ||
| FG100-5115-2C | Cupro-nickel | 230 | 50,000 | 28.8 | 480 | 110 | 230 | 6 | 87 | 6 | 87 | 16 |
| Type | Tube Material | BTU | Boiler kW | ||
| FG100-5115-2C | Cupro-nickel | 580,000 | 170 | ||
Water Flow
As the graphs and table below illustrate, providing the right water flow volume is vital to the performance of the heat exchanger. If the flow rate of either the hot water supply, or the pool water circuit is too low, the heat exchanger will not perform at its designed efficiency and will be unable to transfer all the available heat energy in to the pool water.
Heat Transfer
![]() |
Hot Water | Temperature & Heat Transfer | |||
| Flow rate | 82ºC | 70ºC | 60ºC | 45ºC | |
| l/min | kW | kW | kW | kW | |
| 30 | 90 | 69 | 52 | 27 | |
| 45 | 114 | 87 | 65 | 34 | |
| 60 | 132 | 101 | 76 | 39 | |
| 75 | 147 | 113 | 85 | 44 | |
| 90 | 159 | 122 | 92 | 47 | |
| 100 | 170 | 130 | 98 | 51 | |
Pressure Drop

Installation

| Restricted Product | No |
|---|---|
| RRP | 1052.42 |