InverX20 Inverter Heat Pump
Get the Best Price—Guaranteed
Found a better deal elsewhere? Let us help. Click here to complete a quick form, and we’ll match or beat any price you’ve received, ensuring you get the best value for your investment.
Unleash Unmatched Efficiency with the Fairland InverX20 Full-Inverter Heat Pump
Achieve superior energy savings and year-round comfort with the Fairland InverX20. Powered by Fairland's innovative Full-Inverter technology, this heat pump is designed to deliver maximum performance while significantly reducing energy costs. Its self-developed control system, combined with advanced 3D heat-exchanging technology, intelligently optimises gas flow for industry-leading COP performance—saving you money and enhancing your comfort.
Enjoy maximum comfort, lower energy bills, and unbeatable savings.
Get the Best Price—Guaranteed
Found a better deal elsewhere? Let us help. Click here to complete a quick form, and we’ll match or beat any price you’ve received, ensuring you get the best value for your investment.
Unleash Unmatched Efficiency with the Fairland InverX20 Full-Inverter Heat Pump
Achieve superior energy savings and year-round comfort with the Fairland InverX20. Powered by Fairland's innovative Full-Inverter technology, this heat pump is designed to deliver maximum performance while significantly reducing energy costs. Its self-developed control system, combined with advanced 3D heat-exchanging technology, intelligently optimises gas flow for industry-leading COP performance—saving you money and enhancing your comfort.
Enjoy maximum comfort, lower energy bills, and unbeatable savings.
InverX20 Heat Pump
Introducing the impressive Fairland InverX20 Full-Inverter heat pump based on Fairland's original Full-Inverter technology. The heat pump features Fairland's self-developed control system, perfectly matching the inverter compressor and the extreme 3D heat-exchanging technology. This unique technology intelligently optimises the gas flow rate to maximise the COP performance.
3D Heat Exchanging Tech:
Fairland has developed a new generation of 3D heat-exchanging technology that redefines titanium heat exchangers, increasing the exchanging area by 30% and improving efficiency by 30%.
3 Modes to Efficiently Control Consumption:
- Turbo Mode: 120% power to reach set temperature
- Smart Mode: 20-100% power based on how your water temperature
- Silent Mode: 20-60% power helps you save energy while maintaining a quiet, peaceful pool environment.

Features:
- 20 X Energy Saving COP20, 1kw Input = 20kW Output Max
- All Year Round Use - 4 Season Functionality, contact us for sizing.
- Ability to both cool and heat, with a minimum temperature of 12°
- maintaining a quiet, peaceful pool environment.
- Operation from -20°
Specifications of The InverX20 Inverter Swimming Pool Heat Pump
|
Model |
X20-14 |
X20-18 |
X20-22 |
X20-26 |
X20-32 |
|
Advised pool volume (m3) |
30~50 |
40~65 |
45~75 |
55~90 |
65~105 |
|
Working air temp (°C / °F F) |
-20 ~43 / -4 ~109 |
||||
|
Performance Condition: Air 26°C / 80°F F, Water 26°C / 80°F F, Humidity 80% |
|||||
|
Heating capacity (kW) in Turbo mode |
14.0 |
18.5 |
22.0 |
26.5 |
32.0 |
|
Heating capacity (kW) in Smart mode |
12.0 |
15.4 |
18.0 |
22.5 |
27.5 |
|
COP |
20.0~7.8 |
19.6~7.2 |
21~7.4 |
20.7~7.5 |
20.0~7.3 |
|
COP at 50% capacity |
15.2 |
14.8 |
15.3 |
15.2 |
15.1 |
|
COP at 20% capacity |
20.0 |
19.6 |
21.0 |
20.7 |
20.0 |
|
Performance Condition: Air 15°C / 59°F F, Water 26°C / 80°F F, Humidity 70% |
|||||
|
Heating capacity (kW) in Turbo mode |
9.2 |
12.5 |
14.8 |
18.2 |
22.3 |
|
Heating capacity (kW) in Smart mode |
7.5 |
10.4 |
12.5 |
15.0 |
18.5 |
|
COP |
8.1~5.4 |
8.2~5.1 |
9.0~5.4 |
9.5~5.5 |
8.3~5.4 |
|
COP at 50% capacity |
7.3 |
7.3 |
7.6 |
8.0 |
7.6 |
|
COP at 20% capacity |
8.1 |
8.2 |
9.0 |
9.5 |
8.3 |
|
Performance Condition: Air 7°C / 45 °F F, Water 26°C / 80°F F, Humidity 90% |
|||||
|
Heating capacity (kW) in Turbo mode |
7.4 |
10.5 |
11.8 |
15.5 |
17.8 |
|
COP |
7.1~4.6 |
7.0~4.4 |
7.4~4.5 |
7.3~4.7 |
7.3~4.7 |
|
Sound pressure at 1m dB(A) |
37.8~45.9 |
41.5~47.3 |
41.9~49.5 |
39.7~49.8 |
42.1~50.3 |
|
Sound pressure of 50% capacity at 1m dB(A) |
40.3 |
42.5 |
43.3 |
43.1 |
45.2 |
|
Sound pressure at 10m dB(A) |
17.8~25.9 |
21.5~27.3 |
21.9~29.5 |
19.7~29.8 |
22.1~30.3 |
|
Power supply |
230V /1 Ph / 50Hz |
||||
|
Rated input power (kW) at air 15°C / 59°F |
0.19~1.7 |
0.25~2.45 |
0.27~2.74 |
0.32~3.31 |
0.46~4.1 |
|
Rated input current (A) at air 15°C / 59°F |
0.83~7.39 |
1.09~10.65 |
1.17~11.9 |
1.39~14.4 |
2.01~17.8 |
|
Advised water flux (m³/h) |
3~4 |
4~6 |
6.5~8.5 |
8~10 |
10~12 |
|
Water pipe in-out Spec (mm) |
48.3 |
||||
|
Net Dimension L × W × H (mm) |
945×432×660 |
1045×432×660 |
1195×432×760 |
1072×536×956 |
1264×536×956 |
|
Net Weight (kg) |
65 |
73 |
82 |
100 |
122 |
What Circuit Breaker is Required
| Model | X20-14 | X20-18 | X20-22 | X20-26 | X20-32 | |
| Breaker | Rated Current (A) | 15.0 | 20.0 | 22.5 | 24.5 | 28.5 |
| Rated Residual Action Current (mA) | 30 | 30 | 30 | 30 | 30 | |
| Max input current (A) | 12.5 | 16.5 | 18.5 | 20.5 | 24.0 | |
| Fuse (A) | 15.0 | 20.0 | 22.5 | 24.5 | 28.5 | |
| Power Cord (mm2) | 3x2.5 | 3x2.5 | 3x4 | 3x4 | 3x6 | |
| Signal Cable (mm2) | 3x0.5 | 3x0.5 | 3x0.5 | 3x0.5 | 3x0.5 | |
| Restricted Product | No |
|---|