Bowman Heat Exchanger EC100 5113-2T - Titanium
The Bowman Heat Exchanger EC100 5113-2T is an extremely versatile heat exchanger which is suitable for use with both larger spas and hot tubs, or domestic swimming pools up to 90 m³ via a boiler heat source. It features ‘Universal Fit’ composite end covers, for easy installation into pool or spa pipework and a choice of either a titanium, cupro-nickel, or stainless steel tube core.
The Bowman Heat Exchanger EC100 5113-2T is an extremely versatile heat exchanger which is suitable for use with both larger spas and hot tubs, or domestic swimming pools up to 90 m³ via a boiler heat source. It features ‘Universal Fit’ composite end covers, for easy installation into pool or spa pipework and a choice of either a titanium, cupro-nickel, or stainless steel tube core.
Bowman Heat Exchanger EC100 5113-2T - Titanium
When it comes to efficient, high-performance heat transfer for pools and spas, Bowman Heat Exchanger EC100 5113-2T stands out as a top choice. With thousands of units in operation worldwide—from private hot tubs to Olympic-sized pools—Bowman offers reliable and energy-efficient heat transfer solutions for both commercial and residential applications.
Product Benefits:
- Proven: heats spas and hot tubs extremely fast, reducing energy costs
- Easy to install: solvent weld end covers with thermostat pocket
- Durability: salt water and mineral rich fresh water compatible
- Simple to maintain: easy disassembly for routine maintenance
- Titanium models: full 10 year warranty on titanium materials
Specification:

| Type | Tube Material | Typical Pool Capacity | Maximum Pool Water Flow | Maximum Hot Water Temp | Max. Operating Pressure Pool Water | Max. Operating Pressure Hot Water | Weight | |||||
| m3 | gal | m3/ h | l/min | ºC | ºF | bar | psi | bar | psi | kg | ||
| EC100-5113-2T | Titanium | 90 | 20,000 | 12 | 250 | 110 | 230 | 6 | 87 | 6 | 87 | 4.0 |
| Type | Tube Material | BTU | kW | ||
| EC100-5113-2T | Titanium | 170,000BTU | 50 | ||
Water Flow
As the graphs and table below illustrate, providing the right water flow volume is vital to the performance of the heat exchanger. If the flow rate of either the hot water supply, or the pool water circuit is too low, the heat exchanger will not perform at its designed efficiency and will be unable to transfer all the available heat energy in to the pool water.
Heat Transfer
![]() |
Hot Water | Temperature & Heat Transfer | |||
| Flow rate | 82ºC | 70ºC | 60ºC | 45ºC | |
| l/min | kW | kW | kW | kW | |
| 10 | 20 | 16 | 12 | 6 | |
| 20 | 29 | 23 | 17 | 9 | |
| 30 | 35 | 27 | 20 | 11 | |
| 40 | 42 | 30 | 23 | 12 | |
| 50 | 46 | 33 | 25 | 13 | |
| 60 | 50 | 35 | 26 | 14 | |
Pressure Drop

Installation

Universal Fit End Covers
The EC100-5113-2T is supplied with ‘Universal Fit’ composite end covers, designed for use with either 1.5” nominal pipe size (48mm O/D) or metric 50mm O/D pool pipework. The ‘socket union’ component enables either diameter to be accommodated, as shown on the adjacent cross section illustration. To purchase extra please click here.